VCI Packaging: The Four Jar Tests and the Scales That Disagree

Four bodies publish their own jar test for the same property, two of them grade in opposite directions, and the coverage figure buyers ask for is unpublished.


The short answer

VCI leaves its paper or film as a vapor and settles on the metal inside a closed enclosure. The enclosure is part of the specification, not an extra.

Four countries test the same thing, and their scales run opposite ways. A grade of 4 is near failure on one test and near perfect on two others.

Buyers treat VCI like any other material. Pick a paper or a film, wrap the part, and trust the chemistry to do what the datasheet says.

The datasheet is harder to read than that. A VCI claim rests on a jar test, four countries write their own version of that test, and the versions do not score the same way.

Two plain numbers go missing as well. How much one sheet covers, and how close it must sit to the metal, are the first things a buyer asks. Nobody prints either.

This reference covers what the chemistry does and how the four tests differ. It then covers the scale trap, what one public spec does pin down, and the two figures you have to ask for.

4 testsOfficial, for one property
Opposite scalesHigher is better, or worse
1 yearPanel test in the spec
20 hoursSoak all four share

What VCI Actually Does

The chemistry does not stay where you put it. It leaves the paper or film, drifts through the air in the package, and lands as a thin film on bare metal.

That film is what interrupts corrosion, and it reaches places a brush cannot, which is why the method suits assemblies with hollow interiors.

Moving as a vapor comes with a catch. The vapor has to stay concentrated enough to keep working, so it needs a fairly closed space.

So the enclosure counts as part of the specification. A VCI sheet laid in an open crate does very little, because the useful part simply drifts away.

Carrier choice matters for a second reason. VCI paper is paper, bought by corrugated basis weight like any other grade, and that choice has knock-on effects later.

Four Official Tests for One Property

Claims come from a jar test, in which a polished metal panel sits near the VCI material in a sealed jar while damp air does its work. Four separate bodies publish their own version of that test.

Method Body Conditioning A higher grade means
MIL-STD-3010C, Method 4031 US Department of Defense 20 h, 75 °F, 90% RH, glycerin More rust
NACE TM0208 NACE 20 h damp, plus a heating step Better protection
TL 8135-0002 German buying office 20 h dry, then 22 °C and 40 °C Better protection
JIS Z 1542 Japanese Standards Association 20 h at 90% RH, then condensation Staged, read the scale

They agree on the broad shape and split on the detail, since all four condition for twenty hours and almost everything else moves between them.

They prep the metal differently first. The US method polishes at 240 grit then 400, while the German and Japanese ones use 320 grit, and NACE permits polishing by hand or by machine.

Cleaning splits too, because NACE calls for boiling mineral spirits followed by alcohol rinses, and how a panel starts out is part of how it ends up.

Then the damp-air plans part ways. The US method adds 10 millilitres of 26 percent glycerin and produces condensation with cold water in a hollow tube, then runs three hours more.

NACE adds a heat step after the damp conditioning. That lifts humidity and brings condensation on faster.

The German method runs dry for its twenty hours before glycerin goes in. It then warms for two hours at 22 degrees and two more at 40, with no condensation stage at all.

Only the German method uses that dry-then-humid sequence. The Japanese one takes a third route, holding 90 percent humidity for twenty hours and then producing condensation from cold water, with no heat step.

Laboratories have noticed the gap that leaves. One published variant adds a condensation stage to the German method, replacing the water every fifteen minutes throughout the forty-degree phase. That makes its result less comparable to the standard it came from, rather than more comparable to the other three.

The source that sets them side by side is blunt about the upshot. It says the methods differ in details that can sway results, that each one builds a different corrosion environment, and that the spread makes results hard to compare across standards.

The Scales Point Opposite Ways

Here is where a reporting detail turns into a purchasing risk.

The US method grades under 10 times magnification, and a higher number means more corrosion spots. NACE and the German method both grade 0 to 4, and there a higher number means better protection.

So the same digit flips. A 4 is close to a fail on one report and close to ideal on another, and nothing in the digit tells you which.

FOUR METHODS, AND THE SCALES DISAGREEAll four condition for 20 hours. The grading direction is where they split.METHODSOAKGRADE RISES TOWARDMIL-STD-3010C 4031US Dept of Defense75 °F, 90% RH, glycerincondensation stepgoodMORE RUSTNACE TM0208NACE20 h damp, plus heatingdew comes on fasterpoorBETTER COVERTL 8135-0002German buying office20 h dry, then 22 °C, 40 °Cno condensation stepBETTER COVERJIS Z 1542Japanese Standards Association20 h at 90% RH, then dewno heat stepstaged — read the scale

Two scales rise toward better protection and one rises toward worse, so a bare grade settles nothing.

The Japanese method does not settle it either. It grades in stages, using percent of area for the low grades and spot counts under a lens for the high ones.

All of which gives you one short question for any claim. Ask which method gave the grade, because without it the number is a digit rather than a result. The direction of its scale cannot be inferred from the figure alone.

Ask how hard the test was, too. The same comparison calls NACE the method that favors chemistry carried by water vapor. It rates the US and Japanese methods slightly less aggressive, and the German one typically the least aggressive of the four.

What a Public Spec Does Pin Down

Some of this is settled, because a United States military specification for VCI-treated paper sets real requirements, and they ask rather more than a datasheet suggests.

Several of them are pass or fail by eye. Copper in the vapor must show no pits, etching or change of color, and a polished steel panel must show no corrosion, etching or pits.

Each criterion carries a named method behind it, which is what makes the specification auditable. The vapor inhibitor check runs under Federal Standard 101 Method 4031 Procedure B, and contact corrosivity under Method 3005. Blocking resistance runs under Method 3003 Procedure A, and the tear figure under ASTM D689.

Two further requirements are easy to overlook. Markings have to stay clear and legible after two hours in a circulating water bath. The paper must also prove compatible with the MIL-PRF-131 barrier material it gets sealed inside.

One of those runs twice, since the same vapor test repeats after exhaustion, so the paper has to work and then keep working once the easily available chemistry has gone.

Touch gets its own test, on carbon steel panels read after twenty hours. Paper that protects by vapor can still mark the metal it rests on, and the specification separates the two questions.

The vapor test also shows that the method discriminates. Treated panels in that paper came out at zero percent corrosion, while the untreated controls ran at roughly 40 percent on the first pass. After exhaustion the controls reached about 62 percent, so the jar measures something real rather than flattering everything placed in it.

The duration requirement is the one worth knowing. Long-term protection asks for no corrosion of steel panels over one year, across four panels.

The paper also has to survive being handled. Burst strength is listed at 40 psi and tear strength at 40 grams-force each way.

One more clause sits beside those. The paper must not harm the barrier bag it gets sealed inside, and that clause matters more than it reads.

A VCI layer that spoils the seal on its own bag has defeated the package. It is the same logic behind treating ESD packaging and moisture barrier as two separate specifications rather than one product.

The Two Numbers Nobody Publishes

Two figures remain unpublished, and they are the two any specification needs most.

The first is coverage, and no source reached states how much volume or surface a single sheet protects, so a package cannot be sized from published data.

The second is separation. Published test rigs suspend the material near the panel without touching it, which establishes that contact is unnecessary and nothing at all about how far is too far.

Treat both as promises the supplier makes, not as facts you look up. Ask for the coverage rate and the maximum separation in writing, against the enclosure you will actually use.

That is the same logic as a tested configuration rather than a material earning approval under UN certified packaging, where what was proven is precisely what you have.

The carrier brings one last knock-on. A paper VCI sheet sealed in a barrier bag carries far more moisture demand than a synthetic insert would, so the desiccant calculation shifts when the corrosion layer does.

Which is the entire specification in one line. Name the method behind the grade, read the scale the right way round, and get coverage and gap committed for your own enclosure.

Common Questions

Does VCI need a sealed package to work?

It needs a fairly closed one. The chemistry protects metal by leaving the carrier as a vapor, so that vapor has to stay concentrated around the part. A sheet in an open crate loses it to the room, which is why the enclosure counts as part of the specification.

Why do two VCI test reports disagree?

They most likely ran different methods. Four bodies write a jar test, and they differ in grit, glycerin, condensation and heating steps. The source that compares them says each one builds a different corrosion environment and that results are hard to match across standards.

Is a higher VCI grade better or worse?

That depends on the method. Under the US military method a higher number means more corrosion. Under NACE and the German method, which grade 0 to 4, higher means better protection. The Japanese method grades in stages. A grade with no method named cannot be read.

How long does VCI protection last?

No general figure is published. The nearest published requirement is a military specification clause asking for no corrosion of steel panels over one year, across four panels. That is a qualification test rather than a service life. Ask the supplier to commit a time for your own enclosure and conditions.

How to weigh this page. The four test methods come from a VCI manufacturer’s published comparison. The specification criteria come from a second manufacturer’s 2003 evaluation paper, which notes the Navy would repeat the testing. Both firms sell VCI, so the framing is commercially interested even where the figures are exact. One detail is worth flagging. That paper’s measured machine-direction tear is 39.0 grams-force against the 40 listed in its own table, and it still reports a pass. A vendor summary table is not the specification text, so draw no conclusion about the product.

Key takeaways

  • VCI protects metal by leaving its carrier as a vapor, so a fairly closed box is part of the specification rather than an accessory.
  • Four bodies write their own jar test for the same property, differing in grit, glycerin, condensation and heating, and results are hard to match across them.
  • The scales run opposite ways: higher means more corrosion under the US military method and better protection under NACE and the German one.
  • A public military specification does set real requirements, including no corrosion of steel panels over one year across four panels, plus 40 psi burst and 40 grams-force tear.
  • Coverage rate and the maximum separation from the metal are printed by nobody, so both belong in a supplier promise for your own box.